We report on the quantitative analysis of scanning transmission X-ray microscopy (STXM) images of gas-filled, poly(vinyl alcohol) (PVA)-based microballoons (MB) in a water environment. A model for the transmitted intensity is proposed on the basis of a perfect spherical shell stabilizing the microballoon. An extension of this model to take into account the deformation of the MBs is also presented. Taking into consideration a density gradient of the shell and the STXM resolution, we were able to explain very precisely two types of experimental STXM profiles observed on gas-filled MBs. This enables the detailed characterization of MB properties such as radius and wall thickness and the determination of their wall density with unprecedented high resolution.

Fernandes, P., Tzvetkov, G., Fink, R., Paradossi, G., Fery, A. (2008). Quantitative analysis of scanning transmission x-ray microscopi images of gas-filled PVA based microballoons. LANGMUIR, 24, 13677-13682 [10.1021/la801898t.].

Quantitative analysis of scanning transmission x-ray microscopi images of gas-filled PVA based microballoons.

PARADOSSI, GAIO;
2008-01-01

Abstract

We report on the quantitative analysis of scanning transmission X-ray microscopy (STXM) images of gas-filled, poly(vinyl alcohol) (PVA)-based microballoons (MB) in a water environment. A model for the transmitted intensity is proposed on the basis of a perfect spherical shell stabilizing the microballoon. An extension of this model to take into account the deformation of the MBs is also presented. Taking into consideration a density gradient of the shell and the STXM resolution, we were able to explain very precisely two types of experimental STXM profiles observed on gas-filled MBs. This enables the detailed characterization of MB properties such as radius and wall thickness and the determination of their wall density with unprecedented high resolution.
2008
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/02 - CHIMICA FISICA
English
Con Impact Factor ISI
Fernandes, P., Tzvetkov, G., Fink, R., Paradossi, G., Fery, A. (2008). Quantitative analysis of scanning transmission x-ray microscopi images of gas-filled PVA based microballoons. LANGMUIR, 24, 13677-13682 [10.1021/la801898t.].
Fernandes, P; Tzvetkov, G; Fink, R; Paradossi, G; Fery, A
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/114646
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact