Analysis of chocolate flavour through gas sensor arrays has been carried out. Two different set of sensors have been tested to assess the performance of the different sensor arrays: metallo porphyrins and gold nanoparticles peptide coated quartz crystal microbalances. Two series of chocolate samples containing differently formulated products (dark, white and milk) have been tested: the former made of samples obtained under standard process conditions, the second including samples added with some volatile compounds associated to degradation processes and/or low quality raw materials to obtain artificially off-flavoured samples. Analysis with both gas sensor arrays resulted in a good discrimination between standard and artificially off flavoured chocolate samples. The best performance was obtained using the gold nanoparticles peptide sensors with over 90% of correctly assigned samples. (C) 2014 Elsevier B.V. All rights reserved.
Compagnone, D., Faieta, M., Pizzoni, D., DI NATALE, C., Paolesse, R., Van Caelenberg, T., et al. (2015). Quartz crystal microbalance gas sensor arrays for the quality control of chocolate. SENSORS AND ACTUATORS. B, CHEMICAL, 207, 1114-1120 [10.1016/j.snb.2014.10.049].
Quartz crystal microbalance gas sensor arrays for the quality control of chocolate
COMPAGNONE, DARIO;DI NATALE, CORRADO;PAOLESSE, ROBERTO;
2015-01-01
Abstract
Analysis of chocolate flavour through gas sensor arrays has been carried out. Two different set of sensors have been tested to assess the performance of the different sensor arrays: metallo porphyrins and gold nanoparticles peptide coated quartz crystal microbalances. Two series of chocolate samples containing differently formulated products (dark, white and milk) have been tested: the former made of samples obtained under standard process conditions, the second including samples added with some volatile compounds associated to degradation processes and/or low quality raw materials to obtain artificially off-flavoured samples. Analysis with both gas sensor arrays resulted in a good discrimination between standard and artificially off flavoured chocolate samples. The best performance was obtained using the gold nanoparticles peptide sensors with over 90% of correctly assigned samples. (C) 2014 Elsevier B.V. All rights reserved.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0925400514012593-main.pdf
solo utenti autorizzati
Licenza:
Copyright dell'editore
Dimensione
846.22 kB
Formato
Adobe PDF
|
846.22 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.