Changes in body weight in relation to changes in body impedance were studied in six male and four female patients before and during dialysis. Before dialysis, fat-free mass from skinfolds was 46.5 +/- 6.8 kg, and total body water calculated from bio-electrical impedance was 36.9 +/- 5.2 kg. Body water expressed as a percentage of fat-free mass was calculated to be 80 +/- 4%. Mean weight loss, which was assumed to be only loss of water, was 2.7 +/- 0.7 kg. Total body impedance increased by 80 +/- 16 omega from 495 +/- 39 omega to 575 +/- 47 omega. Weight loss and increase in body impedance were highly correlated (r = -0.91, P less than 0.001). However, based on prediction formulas for total body water from bio-electrical impedance, the observed weight (water) loss should be associated with an increase in impedance of only 39 +/- 11 omega. It is concluded that the impedance value before dialysis is a relatively low value, due to the low specific resistivity of the excess of extra-cellular water in the body before dialysis. As a consequence, prediction formulas for body composition from bio-electrical impedance, developed in normal hydrated subjects, overestimate body composition (total body water, fat-free mass) in subjects with oedema.

DE LORENZO, A., Barra, P., Sasso, G., Battistini, N., Deurenberg, P. (1991). Body impedance measurements during dialysis. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 45(6), 321-5.

Body impedance measurements during dialysis

DE LORENZO, ANTONINO;BARRA, PAOLO;
1991-06-01

Abstract

Changes in body weight in relation to changes in body impedance were studied in six male and four female patients before and during dialysis. Before dialysis, fat-free mass from skinfolds was 46.5 +/- 6.8 kg, and total body water calculated from bio-electrical impedance was 36.9 +/- 5.2 kg. Body water expressed as a percentage of fat-free mass was calculated to be 80 +/- 4%. Mean weight loss, which was assumed to be only loss of water, was 2.7 +/- 0.7 kg. Total body impedance increased by 80 +/- 16 omega from 495 +/- 39 omega to 575 +/- 47 omega. Weight loss and increase in body impedance were highly correlated (r = -0.91, P less than 0.001). However, based on prediction formulas for total body water from bio-electrical impedance, the observed weight (water) loss should be associated with an increase in impedance of only 39 +/- 11 omega. It is concluded that the impedance value before dialysis is a relatively low value, due to the low specific resistivity of the excess of extra-cellular water in the body before dialysis. As a consequence, prediction formulas for body composition from bio-electrical impedance, developed in normal hydrated subjects, overestimate body composition (total body water, fat-free mass) in subjects with oedema.
giu-1991
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/49 - SCIENZE TECNICHE DIETETICHE APPLICATE
English
Male; Middle Aged; Female; Electric Conductivity; Body Weight; Body Water; Humans; Water Loss, Insensible; Body Mass Index; Adipose Tissue; Aged; Adult; Dialysis
DE LORENZO, A., Barra, P., Sasso, G., Battistini, N., Deurenberg, P. (1991). Body impedance measurements during dialysis. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 45(6), 321-5.
DE LORENZO, A; Barra, P; Sasso, G; Battistini, N; Deurenberg, P
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/11032
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 47
social impact