Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans.

Politi, L., Biondi Zoccai, G., Nocetti, L., Costi, T., Monopoli, D., Rossi, R., et al. (2012). Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 79(1), 97-102 [10.1002/ccd.22947].

Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield

SANGIORGI, GIUSEPPE
2012-01-01

Abstract

Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans.
1-gen-2012
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE
English
Con Impact Factor ISI
Phantoms, Imaging; Occupational Exposure; Radiation Dosage; Scattering, Radiation; Radiation Protection; Coronary Angiography; Humans; Linear Models; Aged; Italy; Multivariate Analysis; Film Dosimetry; Fluoroscopy; Equipment Design; Aged, 80 and over; Disposable Equipment; Occupational Diseases; Middle Aged; Radiography, Interventional; Radial Artery; Radiation Injuries; Male; Female
Politi, L., Biondi Zoccai, G., Nocetti, L., Costi, T., Monopoli, D., Rossi, R., et al. (2012). Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 79(1), 97-102 [10.1002/ccd.22947].
Politi, L; Biondi Zoccai, G; Nocetti, L; Costi, T; Monopoli, D; Rossi, R; Sgura, F; Modena, M; Sangiorgi, G
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/107609
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 88
  • ???jsp.display-item.citation.isi??? 83
social impact