A water-cooled electromagnetic (EM) dipole, for intracavitary hyperthermia, embodying a metallic reflector to give directional characteristics to the SAR and then to the heating pattern in the biological tissue, is considered. The influence of the reflector on the SAR deposition has been theoretically modelled with an EM analysis which uses the method of moments (MOM). A thermal model, based on the heat transfer equation, is used to predict temperature distribution, which exhibits a directivity related to the angular extension of the reflector. Experiments have been carried out in a polyacrylamide phantom. The temperature distribution detected with a liquid crystal sheet shows fairly good agreement with theoretical predictions.

Biffi Gentili, G., Gori, F., Lachi, L., Leoncini, M. (1994). A Dipole-type Intracavitary Hyperthermic Applicator with a Metallic Reflector: Experiments and Theoretical Analysis. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 10(2), 175-187.

A Dipole-type Intracavitary Hyperthermic Applicator with a Metallic Reflector: Experiments and Theoretical Analysis

GORI, FABIO;
1994-01-01

Abstract

A water-cooled electromagnetic (EM) dipole, for intracavitary hyperthermia, embodying a metallic reflector to give directional characteristics to the SAR and then to the heating pattern in the biological tissue, is considered. The influence of the reflector on the SAR deposition has been theoretically modelled with an EM analysis which uses the method of moments (MOM). A thermal model, based on the heat transfer equation, is used to predict temperature distribution, which exhibits a directivity related to the angular extension of the reflector. Experiments have been carried out in a polyacrylamide phantom. The temperature distribution detected with a liquid crystal sheet shows fairly good agreement with theoretical predictions.
1994
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-IND/10 - FISICA TECNICA INDUSTRIALE
English
Con Impact Factor ISI
Biffi Gentili, G., Gori, F., Lachi, L., Leoncini, M. (1994). A Dipole-type Intracavitary Hyperthermic Applicator with a Metallic Reflector: Experiments and Theoretical Analysis. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 10(2), 175-187.
Biffi Gentili, G; Gori, F; Lachi, L; Leoncini, M
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.