Research into the monitoring and control of oral malodor has nowadays received new stimulus from the importance gained by this phenomenon as a medical and social problem. In this paper the performance of an electronic nose to detect this manifestation has been investigated in order to explore the possibility of using this instrument as a complement to those already existing for the assessment of oral malodor. In particular, a breath sampling procedure has been optimized to maximize the transfer to the sensors of those molecules that are known to be associated with the malodor. The sensitivity of electronic nose sensors to hydrogen sulfide, butyric acid and valeric acid - three compounds known to play a major role in halitosis - has been measured and the results indicate that the threshold limits are compatible with halitosis detection. An experiment with real and artificial samples indicates the possibility of identifying halitosis-affected individuals and of discriminating them according to breath composition.

Pennazza, G., Marchetti, E., Santonico, M., Mantini, G., Mummolo, S., Marzo, G., et al. (2008). Application of a quartz microbalance based gas sensor array for the study of halitosis. JOURNAL OF BREATH RESEARCH, 2(1) [10.1088/1752-7155/2/1/017009].

Application of a quartz microbalance based gas sensor array for the study of halitosis

PAOLESSE, ROBERTO;D'AMICO, ARNALDO;DI NATALE, CORRADO
2008-01-01

Abstract

Research into the monitoring and control of oral malodor has nowadays received new stimulus from the importance gained by this phenomenon as a medical and social problem. In this paper the performance of an electronic nose to detect this manifestation has been investigated in order to explore the possibility of using this instrument as a complement to those already existing for the assessment of oral malodor. In particular, a breath sampling procedure has been optimized to maximize the transfer to the sensors of those molecules that are known to be associated with the malodor. The sensitivity of electronic nose sensors to hydrogen sulfide, butyric acid and valeric acid - three compounds known to play a major role in halitosis - has been measured and the results indicate that the threshold limits are compatible with halitosis detection. An experiment with real and artificial samples indicates the possibility of identifying halitosis-affected individuals and of discriminating them according to breath composition.
2008
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-INF/01 - ELETTRONICA
Settore CHIM/07 - FONDAMENTI CHIMICI DELLE TECNOLOGIE
English
Con Impact Factor ISI
breathing; halitosis; medical instrumentation
Article number: 017009
Pennazza, G., Marchetti, E., Santonico, M., Mantini, G., Mummolo, S., Marzo, G., et al. (2008). Application of a quartz microbalance based gas sensor array for the study of halitosis. JOURNAL OF BREATH RESEARCH, 2(1) [10.1088/1752-7155/2/1/017009].
Pennazza, G; Marchetti, E; Santonico, M; Mantini, G; Mummolo, S; Marzo, G; Paolesse, R; D'Amico, A; DI NATALE, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/101428
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 24
social impact