A reliable transverse emittance measurement for high-brightness electron beams is of utmost importance for the successful development of fourth generation light sources and for the beam transport in plasmabased accelerators. When the beam exhibits a significant energy spread, typical quadrupole scan emittance measurements may be affected depending on the beam properties and on the quadrupoles arrangement. The emittance degradation induced by chromatic effects in measurements involving magnetic lattices is evaluated analytically for different configurations. Analytical and numerical calculations compared with measurements have been used to evaluate the consequent error on the emittance value measured for single and double quadrupole schemes and for typical operating conditions at the SPARC facility

Mostacci, A., Bellaveglia, M., Chiadroni, E., Cianchi, A., Ferrario, M., Filippetto, D., et al. (2012). Chromatic effects in quadrupole scan emittance measurements. PHYSICAL REVIEW SPECIAL TOPICS. ACCELERATORS AND BEAMS, 15, 82802 [10.1103/PhysRevSTAB.15.082802].

Chromatic effects in quadrupole scan emittance measurements

CIANCHI, ALESSANDRO;
2012-08-23

Abstract

A reliable transverse emittance measurement for high-brightness electron beams is of utmost importance for the successful development of fourth generation light sources and for the beam transport in plasmabased accelerators. When the beam exhibits a significant energy spread, typical quadrupole scan emittance measurements may be affected depending on the beam properties and on the quadrupoles arrangement. The emittance degradation induced by chromatic effects in measurements involving magnetic lattices is evaluated analytically for different configurations. Analytical and numerical calculations compared with measurements have been used to evaluate the consequent error on the emittance value measured for single and double quadrupole schemes and for typical operating conditions at the SPARC facility
23-ago-2012
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/01 - FISICA SPERIMENTALE
English
Con Impact Factor ISI
quadrupole, emittance, chromatics effect
Mostacci, A., Bellaveglia, M., Chiadroni, E., Cianchi, A., Ferrario, M., Filippetto, D., et al. (2012). Chromatic effects in quadrupole scan emittance measurements. PHYSICAL REVIEW SPECIAL TOPICS. ACCELERATORS AND BEAMS, 15, 82802 [10.1103/PhysRevSTAB.15.082802].
Mostacci, A; Bellaveglia, M; Chiadroni, E; Cianchi, A; Ferrario, M; Filippetto, D; Gatti, G; Ronsivalle, C
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
2012_PRSTAB_effetticromatici.pdf

accesso aperto

Licenza: Creative commons
Dimensione 1.4 MB
Formato Adobe PDF
1.4 MB Adobe PDF Visualizza/Apri

Questo articolo è pubblicato sotto una Licenza Licenza Creative Commons Creative Commons

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/101214
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 56
  • ???jsp.display-item.citation.isi??? 39
social impact