Abstract Objectives: This study compared: 1) the accuracy of three different electronic apex locators (EALs) in detecting the apical foramen ex-vivo under clinical conditions; 2) the accuracy of digital radiography and EALs in determining the K-file position in the root canal; 3) the accuracy of two different radiographic planes; (4) the precision of #10, #15, and #20 K-files in electronic measurements; 5) the precision of EALs in relation to the dental anatomy classification (anterior, bicuspids, and molars). Materials and methods: The length of 101 extracted human teeth was measured with three different EALs (Endex, Propex II and Root ZX), with RVG and compared to the actual length. Experimental procedures were performed using an endodontic training kit (Pro-Train). Results: The statistical analysis showed that Endex and Propex II were more accurate than Root ZX in determining the working length (WL). The t-test showed no statistically significant difference of accuracy between the two radiographic planes examined. The t-test showed no significant difference between the three different K-file size measurements. EALs and RVG are less accurate in anterior teeth. Conclusions: To prevent overestimation of the root canal length using the EALs tested, 1 mm should be subtracted from the measurement on the ‘‘APEX’’ mark. Instrument sizes did not affect the accuracy of EALs. EALs showed to be more accurate in determining the WL than RVG. 2011 Societa` Italiana di Endodonzia. Published by Elsevier Srl. All rights reserved.

Cianconi, L., Angotti, V., Felici, R., Conte, G., Mancini, M. (2011). Precisione nella determinazione della lunghezza di lavoro mediante localizzatori elettronici d’apice, radiologia digitale e prova visiva: presentazione di una nuova metodica sperimentale di indagine – uno studio ex-vivo. Exact determination of the working length by electronic apex locators, digital radiology, and visual test: presentation of a new experimental research strategy – an ex-vivo study. GIORNALE ITALIANO DI ENDODONZIA, 25(1), 24-32.

Precisione nella determinazione della lunghezza di lavoro mediante localizzatori elettronici d’apice, radiologia digitale e prova visiva: presentazione di una nuova metodica sperimentale di indagine – uno studio ex-vivo. Exact determination of the working length by electronic apex locators, digital radiology, and visual test: presentation of a new experimental research strategy – an ex-vivo study.

CIANCONI, LUIGI;
2011-01-01

Abstract

Abstract Objectives: This study compared: 1) the accuracy of three different electronic apex locators (EALs) in detecting the apical foramen ex-vivo under clinical conditions; 2) the accuracy of digital radiography and EALs in determining the K-file position in the root canal; 3) the accuracy of two different radiographic planes; (4) the precision of #10, #15, and #20 K-files in electronic measurements; 5) the precision of EALs in relation to the dental anatomy classification (anterior, bicuspids, and molars). Materials and methods: The length of 101 extracted human teeth was measured with three different EALs (Endex, Propex II and Root ZX), with RVG and compared to the actual length. Experimental procedures were performed using an endodontic training kit (Pro-Train). Results: The statistical analysis showed that Endex and Propex II were more accurate than Root ZX in determining the working length (WL). The t-test showed no statistically significant difference of accuracy between the two radiographic planes examined. The t-test showed no significant difference between the three different K-file size measurements. EALs and RVG are less accurate in anterior teeth. Conclusions: To prevent overestimation of the root canal length using the EALs tested, 1 mm should be subtracted from the measurement on the ‘‘APEX’’ mark. Instrument sizes did not affect the accuracy of EALs. EALs showed to be more accurate in determining the WL than RVG. 2011 Societa` Italiana di Endodonzia. Published by Elsevier Srl. All rights reserved.
2011
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
English
Apex locator; Working length; Pro-Train; Root ZX; Propex II; Endex.
Cianconi, L., Angotti, V., Felici, R., Conte, G., Mancini, M. (2011). Precisione nella determinazione della lunghezza di lavoro mediante localizzatori elettronici d’apice, radiologia digitale e prova visiva: presentazione di una nuova metodica sperimentale di indagine – uno studio ex-vivo. Exact determination of the working length by electronic apex locators, digital radiology, and visual test: presentation of a new experimental research strategy – an ex-vivo study. GIORNALE ITALIANO DI ENDODONZIA, 25(1), 24-32.
Cianconi, L; Angotti, V; Felici, R; Conte, G; Mancini, M
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
localizzatori GIE-25-1[1].pdf

accesso aperto

Descrizione: Articolo Fulltext
Dimensione 366.2 kB
Formato Adobe PDF
366.2 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/100210
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact