A large acceptance lead-scintillator time-of-flight (TOF) wall has been developed to detect photons, neutrons, and charged particles produced in meson-photoproduction experiments on the proton and on the neutron. A TOF resolution of 600 ps and a position resolution of 11 x 18 cm(2) (full-width at half-maximum) have been achieved. The wall has been successfully used in eta and pi(+) photoproduction experiments as a photon and a neutron detector. This paper reports its design, calibration and performance. (C) 2002 Elsevier Science B.V. All rights reserved.

Kouznetsov, V., Lapik, A., Churikova, S., Girolami, B., Karapetiantz, D., Malyukin, Y., et al. (2002). A large acceptance lead-scintillator time-of-flight wall for neutral and charged particles. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 487, 396-406 [10.1016/S0168-9002(01)02196-9].

A large acceptance lead-scintillator time-of-flight wall for neutral and charged particles

LAPIK, ALEXANDER;D'ANGELO, ANNALISA;SCHAERF, CARLO
2002-01-01

Abstract

A large acceptance lead-scintillator time-of-flight (TOF) wall has been developed to detect photons, neutrons, and charged particles produced in meson-photoproduction experiments on the proton and on the neutron. A TOF resolution of 600 ps and a position resolution of 11 x 18 cm(2) (full-width at half-maximum) have been achieved. The wall has been successfully used in eta and pi(+) photoproduction experiments as a photon and a neutron detector. This paper reports its design, calibration and performance. (C) 2002 Elsevier Science B.V. All rights reserved.
2002
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/04 - FISICA NUCLEARE E SUBNUCLEARE
English
Con Impact Factor ISI
SIGMA-BEAM ASYMMETRY; QUASI-FREE NEUTRONS; PLASTIC SCINTILLATOR; MESON PHOTOPRODUCTION; SPIN OBSERVABLES; DETECTOR; PERFORMANCE; PROTON; GRAAL; ESRF
http://www.sciencedirect.com/science/article/pii/S0168900201021969
Kouznetsov, V., Lapik, A., Churikova, S., Girolami, B., Karapetiantz, D., Malyukin, Y., et al. (2002). A large acceptance lead-scintillator time-of-flight wall for neutral and charged particles. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 487, 396-406 [10.1016/S0168-9002(01)02196-9].
Kouznetsov, V; Lapik, A; Churikova, S; Girolami, B; Karapetiantz, D; Malyukin, Y; Nedorezov, V; Turinge, A; Vorobiev, Y; Abramov, V; D'Angelo, A; Moricciani, D; Nicoletti, L; Ranyuk, Y; Schaerf, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/96500
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 21
social impact