Ion Electron Emission Microscopy (IEEM) can provide an alternative approach to microbeams for micrometric characterization of the sensitivity map to Single Event Effects (SEE) of an electronic device. In IEEM technique, a broad (not focused) ion beam is sent onto the Device Under Test (DUT). Secondary electrons emitted by the target surface during each ion impact are collected and focused by a system of electrostatic lenses and finally imaged by a high-rate and high-resolution position detector. We will report on the IEEM working at the SIRAD irradiation facility located at the 15 MV Tandem of INFN Legnaro National Laboratories. To estimate the IEEM resolution, a SDRAM is a good candidate to be used as a reference target, thanks to the micrometric feature size of the array of memory cells and the precise knowledge of their physical locations. Since an electronic device is not a good secondary electrons emitter, to ensure a copious and uniform emission of secondary electrons from the DUT, a very thin (100 nm) self-standing Silicon Nitride (Si3N4) membrane with a Au deposition (40 nm) is mounted on the top of the SDRAM. The Au/Si3N4 membrane and the underlying SDRAM are irradiated with a heavy ion beam. The physical map of ion impacts detected by the SDRAM is then compared with the one reconstructed by the IEEM in the same 500 ms time interval.

Bertazzoni, S., Bisello, D., Giubilato, P., Kaminsky, A., Mattiazzo, S., Mongiardo, L., et al. (2009). Ion impact detection and micromapping with a SDRAM for IEEM diagnostics and applications. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 56(3), 853-857 [10.1109/TNS.2009.202040].

Ion impact detection and micromapping with a SDRAM for IEEM diagnostics and applications

BERTAZZONI, STEFANO;SALMERI, MARCELLO;SALSANO, ADELIO;
2009-06-03

Abstract

Ion Electron Emission Microscopy (IEEM) can provide an alternative approach to microbeams for micrometric characterization of the sensitivity map to Single Event Effects (SEE) of an electronic device. In IEEM technique, a broad (not focused) ion beam is sent onto the Device Under Test (DUT). Secondary electrons emitted by the target surface during each ion impact are collected and focused by a system of electrostatic lenses and finally imaged by a high-rate and high-resolution position detector. We will report on the IEEM working at the SIRAD irradiation facility located at the 15 MV Tandem of INFN Legnaro National Laboratories. To estimate the IEEM resolution, a SDRAM is a good candidate to be used as a reference target, thanks to the micrometric feature size of the array of memory cells and the precise knowledge of their physical locations. Since an electronic device is not a good secondary electrons emitter, to ensure a copious and uniform emission of secondary electrons from the DUT, a very thin (100 nm) self-standing Silicon Nitride (Si3N4) membrane with a Au deposition (40 nm) is mounted on the top of the SDRAM. The Au/Si3N4 membrane and the underlying SDRAM are irradiated with a heavy ion beam. The physical map of ion impacts detected by the SDRAM is then compared with the one reconstructed by the IEEM in the same 500 ms time interval.
3-giu-2009
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore ING-INF/01 - ELETTRONICA
English
Con Impact Factor ISI
Radiation effects; SDRAM; Single event upset (SEU); TermsIon electron emission microscopy
Alternative approach; Device under test; Electronic device; Feature sizes; High rate; High resolution; Ion electron emission microscopies; Ion impact; Irradiation facilities; Memory cell; Micro beams; National laboratory; Physical locations; Position detector; Reference target; SDRAM; Secondary electrons; Sensitivity map; Single event effects; Single event upset (SEU); Target surface; TermsIon electron emission microscopy; Time interval; Uniform emission; Dynamic random access storage; Electric network analysis; Electron optics; Electrons; Electrostatic lenses; Ion beams; Ion bombardment; Ions; Lenses; Secondary emission; Silicon nitride; Thermoelectric equipment; Uranium powder metallurgy; Radiation effects
Bertazzoni, S., Bisello, D., Giubilato, P., Kaminsky, A., Mattiazzo, S., Mongiardo, L., et al. (2009). Ion impact detection and micromapping with a SDRAM for IEEM diagnostics and applications. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 56(3), 853-857 [10.1109/TNS.2009.202040].
Bertazzoni, S; Bisello, D; Giubilato, P; Kaminsky, A; Mattiazzo, S; Mongiardo, L; Pantano, D; Rando, R; Salmeri, M; Salsano, A; Silvestrin, L; Tessaro, M; Wyss, J
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/55808
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact