Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
We report on the positron to electron ratio in the cosmic radiation over more than one decade in energy from 0.85 to 14 GeV, using the NMSU-WiZard/CAPRICE balloon borne magnet spectrometer. The spectrometer uses a solid radiator RICH detector and a silicon-tungsten calorimeter for particle identification. The proton rejection factor of the two instruments combined is better than 2 × 10-6 between 0.6 and 3 GV/c dropping to 6 × 10-5 at 5 GV/c and 10-4 at 10 GV/c. The data was collected during 23 hours at a mean residual atmosphere of 4.0 g/cm2. Prom a total of 2756 well identified e- and 498 e+ we are able to construct the positron fraction R = e+ /(e+ + e-) as a function of energy with small errors from 0.85 GeV to 14 GeV for the first time. We observe a decreasing ratio in this energy region. This energy dependent behaviour is consistent with the simple leaky box model. The positron fraction in the upper energy bins are in agreement with the latest high energy measurements.
Barbiellini, G., Basini, G., Bellotti, R., Bocciolini, M., Boezio, M., Massimo Brancaccio, F., et al. (1996). The cosmic-ray positron-to-electron ratio in the energy range 0.85 to 14 GeV. ASTRONOMY & ASTROPHYSICS, 309(1).
The cosmic-ray positron-to-electron ratio in the energy range 0.85 to 14 GeV
Barbiellini G.;Basini G.;Bellotti R.;Bocciolini M.;Boezio M.;Massimo Brancaccio F.;Bravar U.;Cafagna F.;Candusso M.;Carlson P.;Casolino M.;Castellano M.;Circella M.;Codino A.;De Cataldo G.;De Marzo C.;De Pascale M. P.;Finetti N.;Francke T.;Giglietto N.;Golden R. L.;Grimani C.;Hof M.;Marangelli B.;Menn W.;Mitchell J. W.;Morselli A.;Ormes J. F.;Papini P.;Perego A.;Piccardi S.;PICOZZA, PIERGIORGIO;Ricci M.;Schiavon P.;Simon M.;SPARVOLI, ROBERTA;Spillatini P.;Spinelli P.;Stephens S. A.;Stochaj S. J.;Streitmatter R. E.;Suffert M.;Vacchi A.;Weber N.;Zampa N.
1996-01-01
Abstract
We report on the positron to electron ratio in the cosmic radiation over more than one decade in energy from 0.85 to 14 GeV, using the NMSU-WiZard/CAPRICE balloon borne magnet spectrometer. The spectrometer uses a solid radiator RICH detector and a silicon-tungsten calorimeter for particle identification. The proton rejection factor of the two instruments combined is better than 2 × 10-6 between 0.6 and 3 GV/c dropping to 6 × 10-5 at 5 GV/c and 10-4 at 10 GV/c. The data was collected during 23 hours at a mean residual atmosphere of 4.0 g/cm2. Prom a total of 2756 well identified e- and 498 e+ we are able to construct the positron fraction R = e+ /(e+ + e-) as a function of energy with small errors from 0.85 GeV to 14 GeV for the first time. We observe a decreasing ratio in this energy region. This energy dependent behaviour is consistent with the simple leaky box model. The positron fraction in the upper energy bins are in agreement with the latest high energy measurements.
Barbiellini, G., Basini, G., Bellotti, R., Bocciolini, M., Boezio, M., Massimo Brancaccio, F., et al. (1996). The cosmic-ray positron-to-electron ratio in the energy range 0.85 to 14 GeV. ASTRONOMY & ASTROPHYSICS, 309(1).
Barbiellini, G; Basini, G; Bellotti, R; Bocciolini, M; Boezio, M; Massimo Brancaccio, F; Bravar, U; Cafagna, F; Candusso, M; Carlson, P; Casolino, M; Castellano, M; Circella, M; Codino, A; De Cataldo, G; De Marzo, C; De Pascale, Mp; Finetti, N; Francke, T; Giglietto, N; Golden, Rl; Grimani, C; Hof, M; Marangelli, B; Menn, W; Mitchell, Jw; Morselli, A; Ormes, Jf; Papini, P; Perego, A; Piccardi, S; Picozza, P; Ricci, M; Schiavon, P; Simon, M; Sparvoli, R; Spillatini, P; Spinelli, P; Stephens, Sa; Stochaj, Sj; Streitmatter, Re; Suffert, M; Vacchi, A; Weber, N; Zampa, N
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/55511
Citazioni
ND
ND
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.