Background: Large-volume culture methods for sterile body fluids employing automated blood-culture systems increase the recovery of microorganisms compared with traditional plate medium methods. However, in many instances a laboratory receives only small-volume samples. Materials/Methods: The URO-QUICK (TM) system (now HB&L), originally used to process urine samples, was evaluated for organism enrichment and determination of microbial count of fluid samples. Fluid specimens were also evaluated for their residual antimicrobial activity (RAA). The procedures were compared with results from a conventional culture procedure. The 546 samples included 106 endotracheal aspirate, 63 bronchoalveolar lavage, 139 sputum, 47 blood, 105 pleural fluid, 26 cerebrospinal fluids, and 41 peritoneal fluid samples as well as 19 other fluids including synovial fluid (n=5), ascitic fluid (n=9), fluids from the drainage of an infected central venous catheter (n=3), abdominal drainage fluid (n=1), and cholecystic fluid (n=1) Results: The URO-QUICK (TM) system allowed the culture of an additional 44 samples (8%, p=0.007) compared with the traditional culturing method. The RAA test demonstrated good concordance with the reference method, showing specificity and positive predictive value of 100% for each, while the sensitivity and the negative predictive value were 67% and 76%, respectively. The microbial counts evaluated using the URO-QUICK (TM) system showed excellent agreement with traditional enumeration methods. Conclusions: The URO-QUICK (TM) system may well represent an excellent alternative to solid medium-based recovery and enumeration methods.

Fontana, C., Favaro, M., Minelli, S., Bossa, M., Altieri, A., Favalli, C. (2009). A novel culturing system for fluid samples. MEDICAL SCIENCE MONITOR, 15(2), BR55-BR60.

A novel culturing system for fluid samples

FAVARO, MARCO;FAVALLI, CARTESIO
2009-01-01

Abstract

Background: Large-volume culture methods for sterile body fluids employing automated blood-culture systems increase the recovery of microorganisms compared with traditional plate medium methods. However, in many instances a laboratory receives only small-volume samples. Materials/Methods: The URO-QUICK (TM) system (now HB&L), originally used to process urine samples, was evaluated for organism enrichment and determination of microbial count of fluid samples. Fluid specimens were also evaluated for their residual antimicrobial activity (RAA). The procedures were compared with results from a conventional culture procedure. The 546 samples included 106 endotracheal aspirate, 63 bronchoalveolar lavage, 139 sputum, 47 blood, 105 pleural fluid, 26 cerebrospinal fluids, and 41 peritoneal fluid samples as well as 19 other fluids including synovial fluid (n=5), ascitic fluid (n=9), fluids from the drainage of an infected central venous catheter (n=3), abdominal drainage fluid (n=1), and cholecystic fluid (n=1) Results: The URO-QUICK (TM) system allowed the culture of an additional 44 samples (8%, p=0.007) compared with the traditional culturing method. The RAA test demonstrated good concordance with the reference method, showing specificity and positive predictive value of 100% for each, while the sensitivity and the negative predictive value were 67% and 76%, respectively. The microbial counts evaluated using the URO-QUICK (TM) system showed excellent agreement with traditional enumeration methods. Conclusions: The URO-QUICK (TM) system may well represent an excellent alternative to solid medium-based recovery and enumeration methods.
2009
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/07 - MICROBIOLOGIA E MICROBIOLOGIA CLINICA
English
Con Impact Factor ISI
Culturing methods; Fluid samples; HB&; Lâ„¢; System; URO-QUICKâ„¢
http://www.medscimonit.com/medscimonit/index.php
Fontana, C., Favaro, M., Minelli, S., Bossa, M., Altieri, A., Favalli, C. (2009). A novel culturing system for fluid samples. MEDICAL SCIENCE MONITOR, 15(2), BR55-BR60.
Fontana, C; Favaro, M; Minelli, S; Bossa, M; Altieri, A; Favalli, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/38992
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact