Background Albeit DES might be considered as a breakthrough against neointimal hyperplasia, concerns on stent thrombosis and increase incidence of in-stent restenosis after multiple DES implantations in complex, long lesions still exist. Hereby, we tried to test efficacy and safety of using PEB in long lesions followed by focal BMS implantation in a pilot multicenter study. Methods This study enrolled 16 patients with long lesions (> 30 mm) that were treated with PEB angioplasty followed by focal stenting with BMS. IVUS was performed before, after PEB and post stenting. Clinical and angiographic follow-up was done at 6 months. The primary end-point was angiographic late lumen loss. Results Patient age was 64.6 ± 8.1 years, 15 (93.7%) were males, and 7 (43.7%) diabetics. Target vessels were most commonly the left anterior descending (6 [31.6%]) and the right coronary artery (6 [31.6%]). PEB diameter was 2.8 ± 0.4 mm with a 31.3 ± 8.9 mm length. Stents per patient were 2.1 ± 0.8. No overlapping stents were deployed. Angiographic success was achieved in 100% of patients. Peri-procedural myocardial infarction occurred in 4 patients (25%). At 6 months follow-up angiography, MLD was 1.55 ± 0.53 mm with a late loss of 0.48 ± 0.52 mm, a binary re-stenosis rate of 2 (12.5%). Conclusion Using PEB with focal stenting by BMS proved to be a feasible, safe, and promising strategy in long coronary lesions. However larger study are needed to confirm these data

Rezq, A., Zoccai, G.b., Latib, A., Romagnoli, E., Aprile, A., Amato, A., et al. (2017). Paclitaxel eluting balloon plus spot bare metal stenting for diffuse and very long coronary disease. (PEB-long pilot study). CLINICAL TRIALS AND REGULATORY SCIENCE IN CARDIOLOGY, 27, 1-7 [10.1016/j.ctrsc.2017.04.001].

Paclitaxel eluting balloon plus spot bare metal stenting for diffuse and very long coronary disease. (PEB-long pilot study)

Romagnoli E.;Aprile A.;Sangiorgi G.
2017-01-01

Abstract

Background Albeit DES might be considered as a breakthrough against neointimal hyperplasia, concerns on stent thrombosis and increase incidence of in-stent restenosis after multiple DES implantations in complex, long lesions still exist. Hereby, we tried to test efficacy and safety of using PEB in long lesions followed by focal BMS implantation in a pilot multicenter study. Methods This study enrolled 16 patients with long lesions (> 30 mm) that were treated with PEB angioplasty followed by focal stenting with BMS. IVUS was performed before, after PEB and post stenting. Clinical and angiographic follow-up was done at 6 months. The primary end-point was angiographic late lumen loss. Results Patient age was 64.6 ± 8.1 years, 15 (93.7%) were males, and 7 (43.7%) diabetics. Target vessels were most commonly the left anterior descending (6 [31.6%]) and the right coronary artery (6 [31.6%]). PEB diameter was 2.8 ± 0.4 mm with a 31.3 ± 8.9 mm length. Stents per patient were 2.1 ± 0.8. No overlapping stents were deployed. Angiographic success was achieved in 100% of patients. Peri-procedural myocardial infarction occurred in 4 patients (25%). At 6 months follow-up angiography, MLD was 1.55 ± 0.53 mm with a late loss of 0.48 ± 0.52 mm, a binary re-stenosis rate of 2 (12.5%). Conclusion Using PEB with focal stenting by BMS proved to be a feasible, safe, and promising strategy in long coronary lesions. However larger study are needed to confirm these data
2017
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE
Settore MED/06 - ONCOLOGIA MEDICA
English
Con Impact Factor ISI
stents, restenosis
https://www.sciencedirect.com/science/article/pii/S2405587516300294
Rezq, A., Zoccai, G.b., Latib, A., Romagnoli, E., Aprile, A., Amato, A., et al. (2017). Paclitaxel eluting balloon plus spot bare metal stenting for diffuse and very long coronary disease. (PEB-long pilot study). CLINICAL TRIALS AND REGULATORY SCIENCE IN CARDIOLOGY, 27, 1-7 [10.1016/j.ctrsc.2017.04.001].
Rezq, A; Zoccai, Gb; Latib, A; Romagnoli, E; Aprile, A; Amato, A; Modena, Mg; Colombo, A; Sangiorgi, G
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
2017-ClinTrialsCard Sangiorgi_PEB_Long_Pilot_Study.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 388.69 kB
Formato Adobe PDF
388.69 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/248256
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact