The paper has been developed in the framework of a larger research program, in which the university of Rome "Tor Vergata" (Italy) and the Yangzhou University (China) are jointly involved to study and preserve historic towers. The research aims to evaluate the risk of collapse of the Huzhu Pagoda in Songjiang County, a leaning tower built in the XI century. Mechanical properties of the masonry material have been obtained by experimental tests on small specimen and the mechanical behaviour of the structure has been evaluated via numerical models. The static analysis of this ancient pagoda constitute a prerequisite base for the evaluation of its structural behavior leading to a suitable maintenance program. The architectural characteristics and damage conditions of the pagoda are key parameters in the preparation of a complex analytical model. The pagoda leans more than six and half degrees, and exhibits some bad structural conditions. Static analysis is carried out via finite-element method in order to establish a reliable numerical model and assess the static risk.

Abruzzese, D., Miccoli, L., Yuan, J. (2009). Mechanical behavior of leaning masonry huzhu Pagoda. JOURNAL OF CULTURAL HERITAGE, 10(4), 480-486 [10.1016/j.culher.2009.02.004].

Mechanical behavior of leaning masonry huzhu Pagoda

ABRUZZESE, DONATO;
2009-01-01

Abstract

The paper has been developed in the framework of a larger research program, in which the university of Rome "Tor Vergata" (Italy) and the Yangzhou University (China) are jointly involved to study and preserve historic towers. The research aims to evaluate the risk of collapse of the Huzhu Pagoda in Songjiang County, a leaning tower built in the XI century. Mechanical properties of the masonry material have been obtained by experimental tests on small specimen and the mechanical behaviour of the structure has been evaluated via numerical models. The static analysis of this ancient pagoda constitute a prerequisite base for the evaluation of its structural behavior leading to a suitable maintenance program. The architectural characteristics and damage conditions of the pagoda are key parameters in the preparation of a complex analytical model. The pagoda leans more than six and half degrees, and exhibits some bad structural conditions. Static analysis is carried out via finite-element method in order to establish a reliable numerical model and assess the static risk.
2009
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore ICAR/09 - TECNICA DELLE COSTRUZIONI
English
Con Impact Factor ISI
Ancient pagoda; cultural heritage; huzhu Pagoda; leaning tower; masonry tower; seismic risk assessment
Abruzzese, D., Miccoli, L., Yuan, J. (2009). Mechanical behavior of leaning masonry huzhu Pagoda. JOURNAL OF CULTURAL HERITAGE, 10(4), 480-486 [10.1016/j.culher.2009.02.004].
Abruzzese, D; Miccoli, L; Yuan, J
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/23545
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 39
social impact