The monitoring of the breathing dynamic characteristics, including the presence of biomarkers in exhaled breath, is of growing interest in non-invasive diagnosis of diseases. The authors describe a wearable radiofrequency identification device hosting a flexible antenna suitable for integration into a facemask and a sensor made of graphene oxide sensitive to the humidity variations. The resulting sensor tag was characterised in reference conditions while its communication performance was estimated by electromagnetic simulations as well as measurements over a simplified model of the human head. Finally, the whole system was tested on a volunteer and was experimentally demonstrated to be capable of detecting the inhalation/ exhalation cycles and abnormal patterns of respiration like the apnea by measuring the changes in graphene oxide resistance.

Caccami, M.c., Mulla, M., Di Natale, C., Marrocco, G. (2018). Graphene oxide-based radiofrequency identification wearable sensor for breath monitoring. IET MICROWAVES, ANTENNAS & PROPAGATION, 12(4), 467-471 [10.1049/iet-map.2017.0628].

Graphene oxide-based radiofrequency identification wearable sensor for breath monitoring

Caccami, Maria Cristina;Di Natale, Corrado;Marrocco, Gaetano
2018-01-01

Abstract

The monitoring of the breathing dynamic characteristics, including the presence of biomarkers in exhaled breath, is of growing interest in non-invasive diagnosis of diseases. The authors describe a wearable radiofrequency identification device hosting a flexible antenna suitable for integration into a facemask and a sensor made of graphene oxide sensitive to the humidity variations. The resulting sensor tag was characterised in reference conditions while its communication performance was estimated by electromagnetic simulations as well as measurements over a simplified model of the human head. Finally, the whole system was tested on a volunteer and was experimentally demonstrated to be capable of detecting the inhalation/ exhalation cycles and abnormal patterns of respiration like the apnea by measuring the changes in graphene oxide resistance.
2018
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-INF/02 - CAMPI ELETTROMAGNETICI
English
Electrical and Electronic Engineering
http://www.ietdl.org/IET-MAP
Caccami, M.c., Mulla, M., Di Natale, C., Marrocco, G. (2018). Graphene oxide-based radiofrequency identification wearable sensor for breath monitoring. IET MICROWAVES, ANTENNAS & PROPAGATION, 12(4), 467-471 [10.1049/iet-map.2017.0628].
Caccami, Mc; Mulla, Mys; Di Natale, C; Marrocco, G
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/207656
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 17
social impact