INTRODUCTION:The original reimplantation technique proposed by David includes securing a cylindrical Dacron tube at the level of the ventriculoaortic junction; the preserved native valve is then sutured within the Dacron graft following their scalloped shape in a fashion similar to that used for implanting a stentless aortic valve. Compared to the remodelling technique, this operation has the clear advantage of being utterly haemostatic, offering a good support to the aortic wall, but more importantly preventing any further dilatation of the aortic annulus. However, it is described a loss of function for the annulus and sinuses of Valsalva with a possible impact on leaflet mobility leading to reduced long term stability of the repair. OUR TECHNIQUE: When the valve was deemed acceptable for preservation in younger patients, the aneurysm was excised, leaving ~5 mm rim of aortic tissue around the native valve and around the coronary ostia. Next, horizontal mattress sutures were placed circumferentially under the aortic valve annulus from inside to out and across a Dacron graft measuring at least 4 mm larger than the annulus .The Dacron graft was seated such that the valve was contained within the graft. The sutures were tied over the appropriate size Hegar dilator placed across the aortic valve in order to avoid constriction of the annulus and left ventricular outflow tract or overplication of the graft. Without stretching the Dacron graft, the 3 commissures were pulled up and fixed at the same height using 4-0 polypropilene double ended sutures placed horizontally from inside to outside. Care is taken, with these externally pledgeted sutures, in narrowing the tube graft creating a new sinotubular junction measuring the same diameter of the annulus. The valve was then attached to the wall of the Dacron graft using the same three sutures starting from each commissure running down to the nadir of the cusps. CONCLUSIONS:The sinuses of Valsalva play a key role in optimizing the aortic root haemodynamics during systole, minimizing energy losses during ejection. Our technique, by fixing the distance between the annulus and the commissures together with intercuspidal trigones, allows the tube graft to stretch vertically only between commissures and reiplanted leaflets with a greater degree at the nadir creating new sinuses. Preserving aortic root function is one of the most important factors influencing long term results in patients undergoing valve sparing operation.

Pisano, C., Asta, L., Mangerini, V., Territo, S., Triolo, O., Ricasoli, A., et al. (2017). Preserving aortic root function in David reimplantation technique. In 31th EACTS Annual Meeting, Vienna (Austria) 7-11 October 2017, Booklet.

Preserving aortic root function in David reimplantation technique

C. Pisano
Writing – Original Draft Preparation
;
L. Asta
Data Curation
;
2017-10-01

Abstract

INTRODUCTION:The original reimplantation technique proposed by David includes securing a cylindrical Dacron tube at the level of the ventriculoaortic junction; the preserved native valve is then sutured within the Dacron graft following their scalloped shape in a fashion similar to that used for implanting a stentless aortic valve. Compared to the remodelling technique, this operation has the clear advantage of being utterly haemostatic, offering a good support to the aortic wall, but more importantly preventing any further dilatation of the aortic annulus. However, it is described a loss of function for the annulus and sinuses of Valsalva with a possible impact on leaflet mobility leading to reduced long term stability of the repair. OUR TECHNIQUE: When the valve was deemed acceptable for preservation in younger patients, the aneurysm was excised, leaving ~5 mm rim of aortic tissue around the native valve and around the coronary ostia. Next, horizontal mattress sutures were placed circumferentially under the aortic valve annulus from inside to out and across a Dacron graft measuring at least 4 mm larger than the annulus .The Dacron graft was seated such that the valve was contained within the graft. The sutures were tied over the appropriate size Hegar dilator placed across the aortic valve in order to avoid constriction of the annulus and left ventricular outflow tract or overplication of the graft. Without stretching the Dacron graft, the 3 commissures were pulled up and fixed at the same height using 4-0 polypropilene double ended sutures placed horizontally from inside to outside. Care is taken, with these externally pledgeted sutures, in narrowing the tube graft creating a new sinotubular junction measuring the same diameter of the annulus. The valve was then attached to the wall of the Dacron graft using the same three sutures starting from each commissure running down to the nadir of the cusps. CONCLUSIONS:The sinuses of Valsalva play a key role in optimizing the aortic root haemodynamics during systole, minimizing energy losses during ejection. Our technique, by fixing the distance between the annulus and the commissures together with intercuspidal trigones, allows the tube graft to stretch vertically only between commissures and reiplanted leaflets with a greater degree at the nadir creating new sinuses. Preserving aortic root function is one of the most important factors influencing long term results in patients undergoing valve sparing operation.
31th EACTS Annua Meeting
Vienna
2017
Rilevanza internazionale
ott-2017
ott-2017
Settore MED/23 - CHIRURGIA CARDIACA
English
David Operation, Sinus of Valsalva, Intercuspidal trigones
Intervento a convegno
Pisano, C., Asta, L., Mangerini, V., Territo, S., Triolo, O., Ricasoli, A., et al. (2017). Preserving aortic root function in David reimplantation technique. In 31th EACTS Annual Meeting, Vienna (Austria) 7-11 October 2017, Booklet.
Pisano, C; Asta, L; Mangerini, V; Territo, S; Triolo, O; Ricasoli, A; Argano, V
File in questo prodotto:
File Dimensione Formato  
EACTS 2017.pdf

accesso aperto

Descrizione: Certificate of attendance
Licenza: Copyright dell'editore
Dimensione 255.79 kB
Formato Adobe PDF
255.79 kB Adobe PDF Visualizza/Apri
EACTS- Vienna Pisano .pdf

accesso aperto

Descrizione: Atto del Congresso
Licenza: Copyright dell'editore
Dimensione 3.25 MB
Formato Adobe PDF
3.25 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/192768
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact