An innovative diamond detector layout is presented that is designed to operate at high temperature under intense neutron and gamma fluxes. It is made of a 500 μm "electronic grade" diamond film with 100 nm thick Ag metal contacts deposited onto each surface of the film by means of thermal evaporation. A thick layer of 6LiF has been deposited on top of one of the two Ag contacts to make the detector sensitive to thermal neutrons. The device was tested at the ISIS spallation neutron source (Rutherford Appleton Laboratory, UK) using the INES beam line. The detector was continuously irradiated for 100 hours in vacuum , exposed to a neutron flux of about 106 n cm−2 s−1 at a temperature . The aim of this experiment was to study the time dependence of the diamond detector performance while operating at high temperature under irradiation, providing a first experimental proof of reliable continuous operation for 100 hours at high temperature in a harsh environment.

Pilotti, R., Angelone, M., Marinelli, M., Milani, E., VERONA RINATI, G., Verona, C., et al. (2016). High-temperature long-lasting stability assessment of a single-crystal diamond detector under high-flux neutron irradiation. EUROPHYSICS LETTERS, 116(4), 42001 [10.1209/0295-5075/116/42001].

High-temperature long-lasting stability assessment of a single-crystal diamond detector under high-flux neutron irradiation

PILOTTI, RICCARDO;MARINELLI, MARCO;MILANI, ENRICO;VERONA RINATI, GIANLUCA;VERONA, CLAUDIO;PRESTOPINO, GIUSEPPE;VINCENTI, MARIA AURORA;PIETROPAOLO, ANTONINO
2016-01-01

Abstract

An innovative diamond detector layout is presented that is designed to operate at high temperature under intense neutron and gamma fluxes. It is made of a 500 μm "electronic grade" diamond film with 100 nm thick Ag metal contacts deposited onto each surface of the film by means of thermal evaporation. A thick layer of 6LiF has been deposited on top of one of the two Ag contacts to make the detector sensitive to thermal neutrons. The device was tested at the ISIS spallation neutron source (Rutherford Appleton Laboratory, UK) using the INES beam line. The detector was continuously irradiated for 100 hours in vacuum , exposed to a neutron flux of about 106 n cm−2 s−1 at a temperature . The aim of this experiment was to study the time dependence of the diamond detector performance while operating at high temperature under irradiation, providing a first experimental proof of reliable continuous operation for 100 hours at high temperature in a harsh environment.
2016
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/01 - FISICA SPERIMENTALE
English
radiation detectors; components and instrumentation; diamond
Pilotti, R., Angelone, M., Marinelli, M., Milani, E., VERONA RINATI, G., Verona, C., et al. (2016). High-temperature long-lasting stability assessment of a single-crystal diamond detector under high-flux neutron irradiation. EUROPHYSICS LETTERS, 116(4), 42001 [10.1209/0295-5075/116/42001].
Pilotti, R; Angelone, M; Marinelli, M; Milani, E; VERONA RINATI, G; Verona, C; Prestopino, G; Montereali, R; Vincenti, Ma; Schooneveld, E; Scherillo, A; Pietropaolo, A
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Pilotti_2016_EPL_116_42001-1.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.18 MB
Formato Adobe PDF
1.18 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/173183
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 18
social impact