This paper presents a very flexible tool for numerically evaluating the small-signal and noise parameters of a transmission linesubject to an arbitrary thermal gradient. Contrary to previous methods, the proposed approach allows straightforwardly taking into account possible variations of electrical parameters along the propagation direction, such as may be expected when temperature ranges between very different values. The main application of the proposed method is cable modeling in noise-figure measurement setups under cryogenic operation: in such circumstances, indeed, the coaxial cables (or waveguide) at the interface between the outside and the inside of the cryogenic chamber are subject to remarkable temperature excursions. As a consequence, significant de-embedding errors may arise if the cables are not correctly modeled, given the very low values of noise figure which are commonly exhibited by cryo-cooled active devices.

Colangeli, S., Cleriti, R., Ciccognani, W., Limiti, E. (2015). Evaluation of coaxial cable performance under thermal gradients. INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 7(3-4), 239-249 [10.1017/S1759078715000069].

Evaluation of coaxial cable performance under thermal gradients

COLANGELI, SERGIO;CICCOGNANI, WALTER;LIMITI, ERNESTO
2015-03-01

Abstract

This paper presents a very flexible tool for numerically evaluating the small-signal and noise parameters of a transmission linesubject to an arbitrary thermal gradient. Contrary to previous methods, the proposed approach allows straightforwardly taking into account possible variations of electrical parameters along the propagation direction, such as may be expected when temperature ranges between very different values. The main application of the proposed method is cable modeling in noise-figure measurement setups under cryogenic operation: in such circumstances, indeed, the coaxial cables (or waveguide) at the interface between the outside and the inside of the cryogenic chamber are subject to remarkable temperature excursions. As a consequence, significant de-embedding errors may arise if the cables are not correctly modeled, given the very low values of noise figure which are commonly exhibited by cryo-cooled active devices.
mar-2015
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-INF/01 - ELETTRONICA
English
Con Impact Factor ISI
Linear and non-linear CAD techniques, Passive components and circuits
Colangeli, S., Cleriti, R., Ciccognani, W., Limiti, E. (2015). Evaluation of coaxial cable performance under thermal gradients. INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 7(3-4), 239-249 [10.1017/S1759078715000069].
Colangeli, S; Cleriti, R; Ciccognani, W; Limiti, E
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/160101
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact