Background A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables. Methods Three doses of the novel polymer-shelled CA (1.5 ml, 3 ml, and 5 ml [5 × 108 microbubbles (MBs)/ml]) and the commercially available CA SonoVue (1.5 ml [2–5 × 108 MBs/ml]) were used. Visual evaluations of ultrasound images of the left ventricle were independently performed by three observers who graded each segment in a 6-segment model as either 0 = not visible, 1 = weakly visible, or 2 = visible. Moreover, the duration of clinically useful contrast enhancement and the left ventricular opacification were determined. During anesthesia, oxygen saturation, heart rate, and arterial pressure were sampled every minute and the effect of injection of CA on these physiological variables was evaluated. Results The highest dose of the polymer-shelled CA gave results comparable to SonoVue. Thus, no significant difference in the overall segment score distribution (2-47-95 vs. 1-39-104), time for clinically sufficient contrast enhancement (20–40 s for both) and left ventricular overall opacification was found. In contrast, when comparing the endocardial border delineation capacity for different regions SonoVue showed significantly higher segment scores for base and mid, except for the mid region when injecting 1.5 ml of the polymer-shelled CA. Neither high nor low doses of the polymer-shelled CA significantly affected the investigated physiological variables. Conclusions This study demonstrated that the novel polymer-shelled CA can be used in contrast-enhanced diagnostic imaging without influence on major physiological variables.

Larsson, M., Larsson, M., Nowak, G., Paradossi, G., Brodin, L., Janerot Sjöberg, B., et al. (2014). Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent. CARDIOVASCULAR ULTRASOUND, 12, 24 [10.1186/1476-7120-12-24].

Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent

PARADOSSI, GAIO;
2014-01-01

Abstract

Background A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables. Methods Three doses of the novel polymer-shelled CA (1.5 ml, 3 ml, and 5 ml [5 × 108 microbubbles (MBs)/ml]) and the commercially available CA SonoVue (1.5 ml [2–5 × 108 MBs/ml]) were used. Visual evaluations of ultrasound images of the left ventricle were independently performed by three observers who graded each segment in a 6-segment model as either 0 = not visible, 1 = weakly visible, or 2 = visible. Moreover, the duration of clinically useful contrast enhancement and the left ventricular opacification were determined. During anesthesia, oxygen saturation, heart rate, and arterial pressure were sampled every minute and the effect of injection of CA on these physiological variables was evaluated. Results The highest dose of the polymer-shelled CA gave results comparable to SonoVue. Thus, no significant difference in the overall segment score distribution (2-47-95 vs. 1-39-104), time for clinically sufficient contrast enhancement (20–40 s for both) and left ventricular overall opacification was found. In contrast, when comparing the endocardial border delineation capacity for different regions SonoVue showed significantly higher segment scores for base and mid, except for the mid region when injecting 1.5 ml of the polymer-shelled CA. Neither high nor low doses of the polymer-shelled CA significantly affected the investigated physiological variables. Conclusions This study demonstrated that the novel polymer-shelled CA can be used in contrast-enhanced diagnostic imaging without influence on major physiological variables.
2014
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/02 - CHIMICA FISICA
English
Con Impact Factor ISI
Contrast agent; Echocardiography; Endocardial border delineation; Microbubbles; Polyvinyl alcohol; Porcine; Ultrasound
Larsson, M., Larsson, M., Nowak, G., Paradossi, G., Brodin, L., Janerot Sjöberg, B., et al. (2014). Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent. CARDIOVASCULAR ULTRASOUND, 12, 24 [10.1186/1476-7120-12-24].
Larsson, M; Larsson, M; Nowak, G; Paradossi, G; Brodin, L; Janerot Sjöberg, B; Caidahl, K; Bjällmark, A
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/115595
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact