In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the reactive ion etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the electrodes results in a shorter travel path for the excess charge carriers, thus contributing to a more efficient charge collection mechanism. The CCE of the device was mapped by means of the ion beam induced charge (IBIC) technique. A 1MeV proton microbeam was raster-scanned over the active area of the diamond detector under different bias voltage conditions, enabling to probe the charge transport properties of the detector up to a depth of 8 ìm below the sample surface. The experimental results, supported by the numerical simulations, show a significant improvement in the 3D detector performance (i.e. CCE, energy resolution, extension of the active area) if compared with the results obtained by standard surface metallic electrodes.

Forneris, J., Lo Giudice, A., Olivero, P., Picollo, F., Re, A., Marinelli, M., et al. (2014). A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors. EUROPHYSICS LETTERS, 108(1) [10.1209/0295-5075/108/18001].

A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors

MARINELLI, MARCO;Verona, C;VERONA RINATI, GIANLUCA;
2014-01-01

Abstract

In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the reactive ion etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the electrodes results in a shorter travel path for the excess charge carriers, thus contributing to a more efficient charge collection mechanism. The CCE of the device was mapped by means of the ion beam induced charge (IBIC) technique. A 1MeV proton microbeam was raster-scanned over the active area of the diamond detector under different bias voltage conditions, enabling to probe the charge transport properties of the detector up to a depth of 8 ìm below the sample surface. The experimental results, supported by the numerical simulations, show a significant improvement in the 3D detector performance (i.e. CCE, energy resolution, extension of the active area) if compared with the results obtained by standard surface metallic electrodes.
2014
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/01 - FISICA SPERIMENTALE
Settore FIS/07 - FISICA APPLICATA (A BENI CULTURALI, AMBIENTALI, BIOLOGIA E MEDICINA)
English
Forneris, J., Lo Giudice, A., Olivero, P., Picollo, F., Re, A., Marinelli, M., et al. (2014). A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors. EUROPHYSICS LETTERS, 108(1) [10.1209/0295-5075/108/18001].
Forneris, J; Lo Giudice, A; Olivero, P; Picollo, F; Re, A; Marinelli, M; Pompili, F; Verona, C; VERONA RINATI, G; Benetti, M; Cannata, D; Di Pietrantonio, F
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
EPL A 3 dimentinal 2014.pdf

accesso aperto

Licenza: Copyright dell'editore
Dimensione 677.96 kB
Formato Adobe PDF
677.96 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/101693
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact