Abstract OBJECTIVES: To evaluate the role of 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET-CT) in the diagnosis of infectious endocarditis (IE). METHODS: We retrospectively examined 27 consecutive patients who were admitted to the Infectious Diseases Department of Tor Vergata University Hospital between 2009 and 2013 with a suspicion of IE. The final IE diagnosis was defined according to the modified Duke criteria, and the microbiological and diagnostic results were collected for each patient. RESULTS: Twenty out of 27 patients had a suspected prosthetic valve endocarditis (PVE) and seven had a suspected native valve endocarditis (NVE). Twenty-five out of 27 patients (92%) had a confirmed diagnosis of IE (18/25 PVE and 7/25 NVE); 16 had a positive echocardiography evaluation and 16 had positive (18)F-FDG-PET-CT findings. Echocardiography showed a higher sensitivity as a diagnostic tool for the detection of IE compared to (18)F-FDG-PET-CT (80% vs. 55%). However, a greater number of PVE had positive (18)F-FDG-PET-CT results compared to those with positive echocardiography findings (11/13 vs. 9/13), and overall 89% (16/18) of confirmed PVE resulted (18)F-FDG-PET-CT positive. Analyzing only the cases who underwent transoesophageal echocardiography, (18)F-FDG-PET-CT showed a sensitivity of 85% in PVE (vs. 69% for echocardiography and 77% for the Duke criteria). All seven patients with NVE had a positive echocardiography and negative (18)F-FDG-PET-CT findings (p<0.001). CONCLUSIONS: The results of this study further highlight the limitations of echocardiography in the diagnosis of PVE and the potential advantages of (18)F-FDG-PET-CT in these cases.

Ricciardi, A., Sordillo, P., Ceccarelli, L., Maffongelli, G., Calisti, G., Di Pietro, B., et al. (2014). 18-Fluoro-2-deoxyglucose positron emission tomography-computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditis. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 28, 219-224 [10.1016/j.ijid.2014.04.028].

18-Fluoro-2-deoxyglucose positron emission tomography-computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditis.

SORDILLO, PASQUALE;SCHILLACI, ORAZIO;PELLEGRINO, ANTONIO;ANDREONI, MASSIMO;SARMATI, LOREDANA
2014-11-01

Abstract

Abstract OBJECTIVES: To evaluate the role of 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET-CT) in the diagnosis of infectious endocarditis (IE). METHODS: We retrospectively examined 27 consecutive patients who were admitted to the Infectious Diseases Department of Tor Vergata University Hospital between 2009 and 2013 with a suspicion of IE. The final IE diagnosis was defined according to the modified Duke criteria, and the microbiological and diagnostic results were collected for each patient. RESULTS: Twenty out of 27 patients had a suspected prosthetic valve endocarditis (PVE) and seven had a suspected native valve endocarditis (NVE). Twenty-five out of 27 patients (92%) had a confirmed diagnosis of IE (18/25 PVE and 7/25 NVE); 16 had a positive echocardiography evaluation and 16 had positive (18)F-FDG-PET-CT findings. Echocardiography showed a higher sensitivity as a diagnostic tool for the detection of IE compared to (18)F-FDG-PET-CT (80% vs. 55%). However, a greater number of PVE had positive (18)F-FDG-PET-CT results compared to those with positive echocardiography findings (11/13 vs. 9/13), and overall 89% (16/18) of confirmed PVE resulted (18)F-FDG-PET-CT positive. Analyzing only the cases who underwent transoesophageal echocardiography, (18)F-FDG-PET-CT showed a sensitivity of 85% in PVE (vs. 69% for echocardiography and 77% for the Duke criteria). All seven patients with NVE had a positive echocardiography and negative (18)F-FDG-PET-CT findings (p<0.001). CONCLUSIONS: The results of this study further highlight the limitations of echocardiography in the diagnosis of PVE and the potential advantages of (18)F-FDG-PET-CT in these cases.
nov-2014
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/17 - MALATTIE INFETTIVE
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Con Impact Factor ISI
18)F-FDG-PET–CT; Cardiac imaging; Echocardiography; Infective endocarditis; Prosthetic valve endocarditis
http://www.sciencedirect.com/science/article/pii/S1201971214015252
Ricciardi, A., Sordillo, P., Ceccarelli, L., Maffongelli, G., Calisti, G., Di Pietro, B., et al. (2014). 18-Fluoro-2-deoxyglucose positron emission tomography-computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditis. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 28, 219-224 [10.1016/j.ijid.2014.04.028].
Ricciardi, A; Sordillo, P; Ceccarelli, L; Maffongelli, G; Calisti, G; Di Pietro, B; Caracciolo, C; Schillaci, O; Pellegrino, A; Chiariello, L; Andreoni, M; Sarmati, L
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1201971214015252-main.pdf

accesso aperto

Licenza: Copyright dell'editore
Dimensione 519.59 kB
Formato Adobe PDF
519.59 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/100694
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 64
social impact